Yes, it is decreasing. If we are talking about ASIC equipment, then the equipment works without fans, modern devices have several quite powerful ones (up to 160 watts each) fans. If we are talking about data-centers and servers, then with immersion cooling, we do not waste energy on chiller, air conditioners and so on.
The insulation of most wires is made of polyvinyl chloride. Despite the fact that polyvinyl chloride has a number of advantages, the cost, good electrical insulating properties, really hardens in immersion baths and that's why :
During operation in an immersion installation, the cable is permanently insulated at a temperature of up to 45-50 degrees.The glass transition temperature of polyvinyl chloride is 75 degrees, but by analogy with freezing, the process begins earlier.Is it scary :Most immersion fluids for single-phase cooling are made on the basis of hydrocarbons.Polyvinyl chloride dissolves incyclohexanon, tetrahydrofuran, dimethylformamide, dichloroethane, little bit in benzene, acetone(swells). It does not dissolve in water, alcohols, hydrocarbons (including gasoline and kerosene). Most immersion fluids for single-phase cooling are made on the basis of hydrocarbons.That is, the insulation does not react with the liquid and does not lose its dielectric properties - the conclusion is not scary.
Modern electronic equipment uses chips made on the basis of silicon crystals. In fact, the chip is a digital integrated circuit, the active elements of which are transistors - while they all work in the mica mode - that is, either the transistor is open or closed. When overclocking, they have to perform their function faster, while switching large currents, which inevitably leads to an increase in energy consumption and heat dissipation. It is possible to consider such a process using the example of a copper conductor. There is a lot of information on the Internet about the cross-section of a conductor for transmitting a current of one or another value. At the same time, the temperature of the conductor always appears next to it. That is, the lower the temperature, the smaller the cross-section can be used (within reasonable limits of course) . It's about the same here. Provided that the appropriate amount of heat is removed, if the temperature of the chip is within acceptable limits, the chips can be safely overclocked. To what extent ? And what happens if I can take away the heat as much as I want? Any chip has a limit. An attempt to overclock above this limit will lead to irreversible degradation of the chip. This can be compared to stretching a spring, at some point it will simply deform and take a new shape, or break.And where is this limit?Modern equipment has a "safe overclocking margin" of 2 times as a rule.And how to understand that "it's enough"? In the process of overclocking, chip consumption grows almost linearly, but at some point it starts to grow sharply. It is possible to accelerate safely only within the linear section.
Technical documentation for OCTAVA Products
This section provides documentation for Octavia installations, descriptions of technical solutions. The section is constantly being updated.
Description of typical Octavia single-phase immersion cooling units
Operating instructions for immersion liquid for single-phase cooling
Operating instructions for the brazed plate heat exchanger
Manual for installation and commissioning of single-phase cooling units Octava
Preparation of equipment for operation in single-phase immersion cooling systems
User's Guide for working with additional systems of Octava installations
Maintenance regulations for Octava single-phase systems
Custom Firmware for main types of ASIC Miners
* The function of automatic lowering of the profile in case of overheating and raising the profile when the temperature is normalized
* AUTO CHIP TUNING – automatic tuning of frequencies, voltage of asic chips (reduction of HW errors, increase of hashrate, extension of asic lifetime)
* turning off fans in immersion cooling, noise reduction, quiet start, maintaining temperature on chips, increasing the lifetime of fans
* Mass password change, SSH port change or disconnection and transfer of config with profile to an unlimited number of ASICs on the same network
* Antivirus - The function of automatic scanning and destruction of ASICs for viruses (ANTBUILD, NIGHT SWITCHER and others)
* FIND ME - Asic search function on the farm
* POWER SAVE - Disconnecting electricity consumption when the Internet or pools are disconnected (on the original BITMAIN firmware, asic continues to consume electricity)
*HOTEL FEE - the function of redirecting part of the capacity to pay for electricity, equipment placement or payment for the maintenance of miners
Прошивки на все модели S19 для запуска асика с Флеш карты. Распаковываем прошивку на карту, вставляем карту в ASIC - включаем И ВСЕ. Скачать
Если Ваша контрольная плата перепаяна, либо Вы используете плату от S17+ , то эту прошивку можно установить в контрольную плату через Веб, "Традиционным" способом Скачать
Уникальная прошивка с новым интерфейсом, рядом улучшенных функций.
Важно - установка прошивки возможна через веб ПОВЕРХ любой прошивки с традиционным интерфейсом Скачать
Прошивка S17+ с классическим интерфейсом.
Уникальная прошивка с новым интерфейсом, рядом улучшенных функций. Для моделей S17/S17Pro
Важно - установка прошивки возможна через веб ПОВЕРХ любой прошивки с традиционным интерфейсом Скачать
Прошивка S17/S17 Pro с классическим интерфейсом.
ВНИМАНИЕ : ПЕРЕД УСТАНОВКОЙ ПРОШИВКИ НЕОБХОДИМО РАЗБЛОКИРОВАТЬ SSH !!!!
РАЗБЛОКИРОВКА SSH работает на всех версиях прошивок до декабря 2019 года
Если у вас версия прошивки декабрь 2019 или еще новее то вам необходимо использовать SD образ выложенный у нас на сайте. Версию прошивки можно посмотреть в разделе System - file system version
Скачать
Lorem ipsum dolor sit amet, eam et reque justo quidam, te est audire persius. Duis meis quas vim ex, ius no oblique phaedrum pertinacia. Ornatus referrentur nec cu, dicam dolore vivendum ne mea. Usu bonorum inermis efficiantur
Lorem ipsum dolor sit amet, eam et reque justo quidam, te est audire persius. Duis meis quas vim ex, ius no oblique phaedrum pertinacia. Ornatus referrentur nec cu, dicam dolore vivendum ne mea. Usu bonorum inermis efficiantur
Старый добрый, надежный как танк Т-34 S9 Скачать
Прошивки для популярных Scrypt майнеров Скачать
Прошивка с поддержкой работы в иммерсионном охлаждении для Whatsminer M20. Без DevFee, Разработчик - Whatsminer Original. Скачать
Lorem ipsum dolor sit amet, eam et reque justo quidam, te est audire persius. Duis meis quas vim ex, ius no oblique phaedrum pertinacia. Ornatus referrentur nec cu, dicam dolore vivendum ne mea.
"Мы постоянно работаем над наполнением данного раздела инструкциями и рекомендациями, что бы помочь улучшить работу с решениями иммерсионного охлаждения компании OCTAVA."
"Мы помогаем решить простые и сложные вопросы по интеграции систем иммерсионного охлаждения и обучаем их дальнейшей эксплуатации. Чудес нет, есть техническая поддержка!"
To install this Web App in your iPhone/iPad press and then Add to Home Screen.